pagPangasinan

Antoy Coolant?

Nov 29, 2025

Mangiter na mensahe .

Antoy Coolant?

Say coolant et samay ondadalan ed battery pack mo ya mangaamper ed saray selula ya manluto. Simpli labat so konsepto balet dakel so totoon nalilingo.

Diad EV tan ESS ya aplikasyon et pantotongtongan tayo so glycol-water mix ya onliliber ed ambetel iran plato odino cooling channels ya aka-machine ed istruktura na pack. Say pluido et mangaala na petang manlapud saray selula, iyakar tod chiller o radiator, ipelag toy petang, tan ompawil pian mangala na dakel ni. Mantultuloy ya ombatik so loop legan ya aktibo so pack.

 

Say mismon pluido

 

Lingwanan mo so antokaman ya amtam nipaakar ed coolant na luluganan. Say berdin Prestone ya nanlapud AutoZone et maneral na battery pack. Saray corrosion inhibitors ed conventional antifreeze et ionic compounds-mankokondukta ira na kuryente. No ipaandar mo itan ed 400V pack, mankekerew ka na ground faults.

Say coolant na baterya et kaukolan ya makasumpal ed duaran kakaukolanen ya ag-iimanoen na regular ya antifreeze:

Electrical resistivity above 100 kΩ·cm minimum. Most OEMs spec 150 kΩ·cm or higher. Tesla's spec calls for >200 kΩ·cm ed balon pano.

Say karga na ion et abeba nen 25 ppm. Ibabaga na arum ya specs ya 10 ppm. Saya so rason no akin ya agmo nayarin usaren so distilled water tan i-mix so sarilim-say glycol a mismo et kaukolan ya ultra-pure.

Say BASF Glysantin G40 tan Arteco Havoline XLC so duaran mabetbet mon nanengneng ed uma. Say Chevron et manggagawa met na espisipikon pormulasyon parad baterya. Manbili iratan na $40-60 kada galon kumpara ed $12-15 parad regular ya OAT coolant. Sulit.

 

coolant

 

Mix Ratio

 

50/50 ethylene glycol ed deionized water so estandarte. Wala ray lalakin ombabatik na 60/40 ed ambetel iran klima. Say onsulok ed 60% ya glycol et talagan makasakit ed sika-ontagey so viscosity, onleksab so heat transfer, mas mankimey so pump.

Say freezing point math:

50/50 ya mix et manyelo ed kaliberliber na -37 degree

60/40 so mamaarap ed sika ed nayarin -52 degree

Say puron glycol et manyelo ed -12℃(on, no iyarum so danum et mamaabeba ed freeze point, makapakelaw so chemistry)

Parad karaklan ed North America et ayos labat so 50/50. No mangipapawit kay pack ed Minnesota o Alberta, mitongtong kad thermal engineer mo pian magmaliw kan mas mayaman.

 

coolant

 

Flow Rate

 

Dia so pakanengnengan ko na sankarakelan a pakawetwet. Saray totoo et balanglan manpapasobra odino manpapaspas ed saratan.

Aliwan komplikado so kalkulasyon. Kaukolan mon amtaen so taloran bengatla: no panon karakel so petang ya ipapaway na pakete, no antoy itagey na temperatura ya nayarian mon itepel ed interon circuit, tan say espisipikon petang na coolant mo.

Parad 50/50 EG/danum ya mix, say espisipikon petang et manga 3.3 kJ/kg·K. Say karakel to et manga 1.07 kg/L.

Ibaga tayon walay 75 kWh ya pakete ya manggagawa na 2C ya discharge. Saya so 150 kW ya output. Pigura 5-6% ya pakawalaan na petang ed satan a kapeles-tawagen itan ya 8 kW ya thermal load. No labay mon pansiansiaen so inlet-to-outlet delta ed silong na 4 degree:

8000 W ÷ (1.07 kg/L × 3300 J/kg·K × 4 K) × 60=34 L/min

Sakey itan a peteg a bilang manlapud peteg a proyekto. Say aktual ya pump ya in-spec'd mi et 40 L/min pian nawalaan kami na headroom.

Maslak ya pasaheron EV packs et manbiabiahe na 8-15 L/min no normal so karga na panagmaneho. Onlelereg legan na maples ya panagkarga odino mansiansian atagey so kuryente.

 

Antoy Ag-agawa

 

Nanengneng so pigaran paraan na inkagba ed loob na saray taon.

Aliwan klase na coolant.Say tindaan et mansumpal na tradisyonal ya antifreeze legan na serbisyo. Ondarakel so konduktibidad. Anengneng na BMS so depekto ed panag-isolate, insara so pack. No masuwerte ka et mangibabantak labat na code. No ag ka masuwerte et makala kay internal arcing.

Kontaminasyon.Importante so kalidad na danum. Sakey a pasen ya nantrabahoan ko et angusar na danum ed gripo parad inmunan panagpano lapud "ondalan itan ed deionizer anggan panon." Likud no ag da labay so deionizer. Say chloride content et 180 ppm. Kaukolan ya i-flush so interon sistema tan salatan iray cold plates-$40k ya trabaho ed $200k ya installation.

Say inkagba ed ilalabas na panaon.Say glycol et man-oxidize. Manporma na glycolic acid, insan oxalic acid. Onbaba so pH. Saray mangaamper ed panag-apag et naupot. Ibabaga na saray OEM ya 4-5 taon ya service interval balet anengneng ko ya aderal so coolant ed loob na 2 taon diad saray lugar ya atagey so temperatura to. Tinaon ya suboken.

Dagem ed sistema.Say pangi-bleeding na EV cooling loops et mairap. Saray bulsa na dagem so pansengegan na hot spots. Say selula ya walad silong na bula et 8-10℃ya mas ambetel nen saray kakaabay to. Maples ya itatatken, onkakapuy so kapasidad, tan diad kaunoran et walay warranty claim.

 

Pansubok ed Kondisyon na Coolant

 

Kaukolan moy taloran sukat:

Say pH-fresh coolant et manlapud 7.8 anggad 8.5 depende ed inkaporma. Say leksab na 7.0 et mankabaliksan ya naupot so inhibitor package. Umanen mo.

Wala ray portable ya metro ya resistivity- balet ta mabmabli iratan. Mangiter na sample ed laboratoryo no anggapo. Antokaman ya walad silong na 50 kΩ·cm et onkakapuy.

Epektibo so glycol concentration-refractometer. $30 ya kagawaan, mangala na 10 segundo. I-check mo no walay dilution manlapud condensation odino walay mangiiter na diretso ya danum.

Wala ray armada ya manggagawa na programa ya singa oil analysis, mangipapawit na sample ed Polaris Labs o Blackstone kada 6 bulan. Sobra parad karaklan ya aplikasyon balet makatunongan parad angkakabaleg iran instalasyon.

 

coolant

 

Direktan Panag-ilog vs Agdirektan Panagpaliis

 

Amin ya walad tagey et mangipapasen ya say pluido et ondadalan ed saray kanal, ya agbalot makasabi ed saray selula. Saya so 95% na walad paway.

Say direktan pangipalgep et duma. Saray selula et walad sakey a bath na dielectric fluid. Anggapoy cold plates, anggapoy thermal interface material, say pluido et direktan makakontak ed lata. Mas maong so pangiyalis na petang. Say inkakomplikado et abeba ed arum a paraan, mas atagey ed arum.

Saray pluido et mandumaan met. 3M Novec tan Solvay Galden so manunan ngaran. Saraya so fluorinated compounds, alablabas so konduktibidad da, chemically inert. Ontan met, alablabas so bili to-$300-400 kada litro parad pigaran pormulasyon.

Say direktan immersion et ompapatnag ed grid storage tan pigaran high-performance ya aplikasyon na luluganan. Aliwa ni ya mainstream balet say thermal performance et mairap ya labanan.

 

Spec Sheet

 

Maples ya reperensya no antoy nengnengen no mansasaliw na battery coolant:

Parametro Puntirya
Base Ethylene glycol, virgin grade
Resistivity >150 kΩ·cm (>100 kΩ·cm ya sankaabebaan)
pH 7.8 - 8.5
Chloride <25 ppm
Sulfate <25 ppm
Reserve alkalinity >3 mL
Punto na yelo (50/50) -37℃o mas abeba
Saray estandarte ya mipara ASTM D3306, SAE J1034

 

Alaen so MSDS tan technical data sheet ed supplier mo. No ag ira makapangiter na resistivity data, mananap kay sananey ya supplier.

Ipawit so Pantepet